使用了dell的 SAS 6i/R LSISAS1068E 此种原带的命令基本无法工作,换个 Lsiutil 即可
下载地址: http://www.kuaipan.cn/file/id_68187849979068418.htm
不带任何参数执行lsiutil,就会进入lsiutil的交互模式。在这个模式下,所有的操作都是通过文本菜单来进行的,举例如下 [root@umail71 lsiutil]#lsiutil LSI Logic MPT Configuration Utility, Version 1.56, March 19, 2008 2 MPT Ports found Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC 1. /proc/mpt/ioc0 LSI Logic SAS1068 B0 105 000a3300 0 2. /proc/mpt/ioc1 LSI Logic SAS1068E B3 105 00192f00 0 Select a device: [1-2 or 0 to quit] 2 1. Identify firmware, BIOS, and/or FCode 2. Download firmware (update the FLASH) 4. Download/erase BIOS and/or FCode (update the FLASH) 8. Scan for devices 10. Change IOC settings (interrupt coalescing) 13. Change SAS IO Unit settings 16. Display attached devices 20. Diagnostics 21. RAID actions 22. Reset bus 23. Reset target 42. Display operating system names for devices 45. Concatenate SAS firmware and NVDATA files 60. Show non-default settings 61. Restore default settings 69. Show board manufacturing information 97. Reset SAS link, HARD RESET 98. Reset SAS link 99. Reset port e Enable expert mode in menus p Enable paged mode w Enable logging Main menu, select an option: [1-99 or e/p/w or 0 to quit] 21 1. Show volumes 2. Show physical disks 3. Get volume state 4. Wait for volume resync to complete 23. Replace physical disk 26. Disable drive firmware update mode 27. Enable drive firmware update mode 30. Create volume 31. Delete volume 32. Change volume settings 33. Change volume name 50. Create hot spare 99. Reset port e Enable expert mode in menus p Enable paged mode w Enable logging RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 1 1 volume is active, 2 physical disks are active Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) Volume Name: Volume WWID: 01e4c8dbc95a53e3 Volume State: optimal, enabled Volume Settings: write caching disabled, auto configure, priority resync Volume draws from Hot Spare Pools: 0 Volume Size 139392 MB, 2 Members Primary is PhysDisk 1 (Bus 0 Target 9) Secondary is PhysDisk 0 (Bus 0 Target 1) RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 命令行模式举例如下: lsiutil -p1 -a 21,1,0,0,0 和上边菜单操作一样,只不过不用手动去选择菜单项了 lsiutil -p 1 -i –s 显示端口1的设置和连接的设备 lsiutil -s 显示所有端口上连接的设备 lsiutil -p 2 -l 1 强制HBA卡端口2连接速度为1Gb [root@umail71 lsiutil]#./lsiutil -p2 -a 21,1,0,0,0 LSI Logic MPT Configuration Utility, Version 1.56, March 19, 2008 2 MPT Ports found Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC 2. /proc/mpt/ioc1 LSI Logic SAS1068E B3 105 00192f00 0 Main menu, select an option: [1-99 or e/p/w or 0 to quit] 21 RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 1 1 volume is active, 2 physical disks are active Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) Volume Name: Volume WWID: 01e4c8dbc95a53e3 Volume State: optimal, enabled Volume Settings: write caching disabled, auto configure, priority resync Volume draws from Hot Spare Pools: 0 Volume Size 139392 MB, 2 Members Primary is PhysDisk 1 (Bus 0 Target 9) Secondary is PhysDisk 0 (Bus 0 Target 1) RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 0 Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0